dc.contributor.author | Shimeles Addisu | |
dc.contributor.author | Birhanu Desalegn | |
dc.contributor.author | Tesfaye Referera | |
dc.date.accessioned | 2020-12-07T07:58:35Z | |
dc.date.available | 2020-12-07T07:58:35Z | |
dc.date.issued | 2012-11 | |
dc.identifier.uri | http://10.140.5.162//handle/123456789/1766 | |
dc.description.abstract | Herein the modifications of a glassy carbon electrode (GCE) with palladium nanoparticles and a palladium film are reported. The response to hydrogen peroxide on the modified electrode was examined using cyclic voltammetry and amperometry (at –0.2 V vs. Ag/AgCl reference electrode in the phosphate buffer solution, pH 7.4). The palladium film and palladium nanoparticle-modified GCE showed a linear response to hydrogen peroxide in the concentration range 10 μM to 14 mM and 1 μM to 14 mM with detection limit of 6.79 and 0.33 μM, respectively. | en_US |
dc.language.iso | en | en_US |
dc.subject | palladium | en_US |
dc.subject | nanoparticles | en_US |
dc.subject | hydrogen peroxide | en_US |
dc.subject | glassy carbon electrode | en_US |
dc.title | Electrochemical determination of hydrogen peroxide at a glassy carbon electrode modified with palladium nanoparticles | en_US |
dc.type | Article | en_US |