Jimma University Open access Institutional Repository

Comparative Analysis of (FACTS) Devices for Power Loss Minimization and Voltage Profile Enhancement in Radial Distribution System: A Case of Sawla Sub-Station.

Show simple item record

dc.contributor.author Kassahun Metena
dc.contributor.author Tefera Mekonnen
dc.contributor.author Biruk Teshome
dc.date.accessioned 2026-11-16T06:47:47Z
dc.date.available 2026-11-16T06:47:47Z
dc.date.issued 2026-12-10
dc.identifier.uri https://repository.ju.edu.et//handle/123456789/10365
dc.description.abstract Radial distribution systems often operate under heavily loaded conditions, resulting in significant power losses and poor voltage regulation. This study presents a comparative analysis of Flexible AC Transmission System (FACTS) devices for power loss minimization and voltage profile enhancement in a 28-bus, 33-kV radial distribution network, with specific application to Sawla Substation Feeder II. The Backward/Forward Sweep load flow method was implemented in MATLAB to evaluate system performance under base-case conditions and after integrating Static VAR Compensator (SVC), Distribution STATCOM (DSTATCOM), and Unified Power Quality Conditioner (UPQC). The assessment was based on voltage profile improvement, active power loss reduction, and overall system performance enhancement. Base-case results showed poor voltage regulation, with a minimum voltage of 0.9417 p.u. at Bus 28 and total active power loss of 2.7086 MW. With SVC integration, voltage levels improved to approximately 0.95 p.u. at weak buses, and active power loss was reduced by 7.54%, demonstrating effective shunt reactive power compensation. DSTATCOM provided further improvement with better dynamic voltage support at the weakest bus, achieving a 10.47% reduction in active power loss and more stable voltage regulation across the feeder. The UPQC achieved the best overall performance, improving voltage stability throughout the system and reducing total active power loss by 11.06%, owing to its combined series and shunt compensation capability. The study concludes that UPQC offers superior technical performance for voltage regulation and loss minimization, while DSTATCOM provides a strong balance between performance and practicality. SVC remains an effective low-cost solution for basic voltage support, making it suitable for less critical applications in radial distribution systems en_US
dc.subject Radial distribution system; FACTS devices; Voltage profile enhancement; Power loss minimization; Reactive power compensation; MATLAB. en_US
dc.title Comparative Analysis of (FACTS) Devices for Power Loss Minimization and Voltage Profile Enhancement in Radial Distribution System: A Case of Sawla Sub-Station. en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search IR


Browse

My Account