Jimma University Open access Institutional Repository

Non Invasive Diabetic Mellitus And Heart Rate Monitoring With Disorder Identification System

Show simple item record

dc.contributor.author Zewdalem Melesse
dc.contributor.author Towfik Jemal
dc.contributor.author T. Bheema Lingaiah
dc.date.accessioned 2022-03-14T06:45:52Z
dc.date.available 2022-03-14T06:45:52Z
dc.date.issued 2019-06
dc.identifier.uri https://repository.ju.edu.et//handle/123456789/6702
dc.description.abstract Diabetic disorder is a form of physiological diseases in which our body blood sugar level increases from its normal level. Inadequate amount of insulin production or unusual response of body cells to insulin production results in increasing of sugar level. The status of our cardiovascular system can be monitored by heart rate counting, which indicates the condition of heart. So previous studies and researches aims on monitoring blood glucose level and heart rate condition in isolated way, as a result the relationship between these two parameters (blood glucose and heart rate) was not considered. But this research focuses to consider both parameters together along with the disorders they bring when the measurement is above or below the normal level for a better treatment. The thesis covers, continuous monitoring of blood glucose level and heart rate in isolated way but on the same system using electronic components and Arduino programming code. Measuring blood glucose concentration best suits at 940nm wavelength, as a result the number selected for the measurement. Heart beat sensor is being used for the measurement of heart rate. Both the prototype and simulation (on proteus) of the system is developed for analysis and validation of the final result. Test results of 40 individuals were measured on the system developed, which leads to relate the relationship between the two parameters. The effect of blood glucose and heart beat on cardiovascular system is also being assessed. The reference values in corresponding with the values obtained, none invasive measurement of blood glucose and heart rate measurement accounts 95% similarity which is clinically acceptable. en_US
dc.language.iso en_US en_US
dc.subject Arduino uno, Blood glucose, Diabetes, Heart rate, en_US
dc.title Non Invasive Diabetic Mellitus And Heart Rate Monitoring With Disorder Identification System en_US
dc.type Thesis en_US


Files in this item