Jimma University Open access Institutional Repository

Effect Of Base Isolation On Soft Storey Reinforced Concrete Building Against Earthquake

Show simple item record

dc.contributor.author Lensa Feyisa
dc.contributor.author Elmer C. Agon
dc.contributor.author Haymanot G/Silasie
dc.date.accessioned 2022-04-05T05:43:27Z
dc.date.available 2022-04-05T05:43:27Z
dc.date.issued 2021-07
dc.identifier.uri https://repository.ju.edu.et//handle/123456789/6904
dc.description.abstract Nowadays, many of reinforced concrete building in urban areas allotted parking, shopping mall areas in some of the stories, which requires large spacing between columns without infill and exterior walls in the structure. Due to this situation, these buildings will have low stiffness or the lateral load resisting systems at those stories is quite less than the stories above or below these stories by 70% percent which is called soft story. For this reason failure of structure starts at these points of weakness is due to discontinuity in mass, stiffness and geometry of structure. The main objective of this study was to evaluate the effect of base isolation in soft storey of medium-rise moment resisting frame building using Response Spectrum Analysis under earthquake load. Adama town was selected as a study area since it is located in the rift valley of Ethiopia which is characterized by a high seismic zone. The study was done on 9- storey moment resisting building with a regular and vertically irregular building model by using ES EN, 2015 code. The core methodology of the research was carried out by modeling and analyzing building with base isolation and without base isolation using ETABS V.18 software. According to analyses result the base isolation in the study increase the time period and storey displacement of the soft storey model due to horizontal flexibility of LRB, both type of soft storey type I &type II increase lateral displacement averagely by 52%-66% and also both soft storey time period increased by relative 45% than the fixed base . in this study the storey acceleration decreased by average 57.85to 64% for type I&II , the other parameter decreased & basic thing is base shear that may cause damage on structure but the base isolation reduce the base shear force by average 36.6%-48.6% that occur in fixed base . Finally base isolation is effective in reducing the base shear, story acceleration, and increasing the fundamental period of fixed base structures. But, further study should be done by considering buildings with different type of vertical irregularity en_US
dc.language.iso en_US en_US
dc.subject -Soft Storey, Stiffness, Base Isolation en_US
dc.title Effect Of Base Isolation On Soft Storey Reinforced Concrete Building Against Earthquake en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search IR


Browse

My Account